Adept Scientific - Norge
Verdens førende software for industri, forskning og utvikling.
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific | Nydalsveien 33 | 0484 Oslo | Norway | Tel: 800 58 997  
UKusdedksvnofi
Hjem
Produkter
Kurs
Services
 Kjøp Online
Downloads
Utdanning
Support
Mitt Adept
Internasjonal |  Om oss |  Kontakt oss |  Presserom |  Jobb


Gå videre

• Ask us a question
• Buy Quality Analyst Now
• View Quality Analyst Pricing
• Find out about Training
• Sign up for a Webinar
• Download a Brochure
• Request a Brochure
• Download a Product Tour
• Download a Demo
• Meet Our Team
• Read our RSS Feeds

Lær mer

NWA Product Overview

Quality Analyst Home
What Quality Analyst
looks like

What charts are available
Database Connectivity
Cpk and DPMO reports
Rave Reviews
System Requirements

Quality Analyst Webserver
Quality Monitor

Siste nytt

What's New in Version 6.1
Quality Analyst
Case Studies

21CFR Part 11 Compliance
Frequently Asked Questions
Current Product
Release Numbers


Service & support

Patches & Downloads
Application Notes
Search the Knowledge Base
Technical Support request

NWA Quality Analyst

What's New in Version 6.1

Why Update to NWA Quality Analyst 6.1?

Many of the improvements in Version 6.1 are aimed at meeting the expanding needs of users engaged in process-improvement programs such as Six Sigma or CAPA. You will benefit from improved drill-down and chart annotation in the Graphics Viewer, inclusion of text reports in grouped output, and the addition of Assignable Cause/Corrective Action capability. Other key improvements address the growing need to integrate SPC and other quality-related programs with plant-level and enterprise manufacturing information systems. Version 6.1 addresses these needs with improved database connectivity setup (particularly for denormalizing data tables), the ability to read specifications from external databases, automatic synchronization of SPC information with records in external databases, and analytical output in XML.

More Powerful Presentation of Chart Data

  • New Graphics Viewer
    It is now easier to present information within your charts so you can more clearly illustrate changes in your processes. The Graphics Viewer includes unlimited data points on SPC charts, text output in groups, the ability to save groups as plot files, user-defined plotting symbols, improved callouts, direct editing of headers and footers, better font and color control, and point-and-click zoom.
  • Rainbow charts
    Configurable green/yellow/red zone options for SPC charts.
  • More graphic formats
    Creates JPG, PNG, and BMP files to enable mixed text and graphics reporting that is easily exported to enterprise applications such as ERP, MES, and LIMS.

Assignable Cause / Corrective Action

You can now select assignable causes and corrective actions from predefined lists or attach ad hoc comments to any data point, supporting quality initiatives and compliance programs such as Six Sigma, ISO 9000, and the FDA’s CAPA.

Improved Drill-Down to Underlying Data

View descriptive information, rule violations, comments, and assignable cause/corrective action for any data point with a single mouse-click.

XML Graphics and Parameter Files

All configuration, parameter, and output files use XML formats, simplifying integration with enterprise applications such as ERP, MES, and LIMS.

Automatic Specification Lookup

NWA Quality Analyst can now read specifications from external databases, which lets you centralize the management of specifications and improve integration with enterprise applications.

SPC Parameters Synchronized with Databases

Automatically links comments, Assignable Cause/Corrective Action, SPC limits, and tagged data to the appropriate record in external databases.

Other Enhancements

  • Full support for Universal Naming Convention (UNC) and long path names - Eliminates the need for mapped drives and simplifies setup in any network environment.
  • Improved Run Charts - Plot up to eight variables and full x-axis labeling for improved multivariable graphing.
  • Improved database denormalization - Helps with the complex task of denormalization during database connectivity.
  • Improved numeric formatting - Specifications maintain significant digits and you have more control over the format of statistical results.
  • Data set limit increased to 500 columns - Larger data sets better support data-rich environments such as multicavity injection molding, electronic assembly, and multiplant studies.
  • Supports Unicode (double-byte text) - Internationalized text and symbol handling now supports Asian characters and other non-ASCII languages in data, chart labels, and text-based reports.
  • Stability analysis regression - Supports food and drug stability studies.


Klar til å bestille

NWA Quality Analyst
Add to shopping basket
NOK 9.545,00
NWA Quality Analyst - 5 user LAN Licence
Add to shopping basket
NOK 54.630,00
Upgrade to NWA Quality Analyst. Includes 12 months maintenance.
Add to shopping basket
NOK 4.590,00

Featured Downloads

SPC Casebook: Unimix Uses NWA Quality Analyst to Build the World's Tallest Building
How to... monitor your processes to ensure quality targets are met with NWA Quality Analyst
How to... use Trend Analysis to identify and evaluate process variations with NWA Quality Analyst
How to... analyse production defects to eliminate waste and ensure quality with NWA Quality Analyst
How to... study Sub Group Data to improve quality performance with NWA Quality Analyst
How to... report quality data to management and customers with NWA Quality Analyst
NWA Quality Analyst 6.1 Demo
NWA Quality Analyst Product Tour

Product Reviews

"The software makes it easy to interpret the data. When we spot a trend that's hugging the upper or lower end of our tolerances, we can identify the problem and work with the operator on a solution...Most people didn't like maths in school, and when they hear the word 'statistic' they tune out. But the software helps employees overcome any uneasiness. We input the measurements and the program produces the chart; there are no complex statistical formulas to compute."
Steve Alloway, Specification Superintendent, Excel Corp.'s pork plant in Beardstown

NWA Quality Analyst has improved our potential for a continual cycle of improvement and quality has already markedly improved...SPC using NWA Quality Analyst [is] very flexible and a great improvement over manual methods.
Alex Phipps, Manager of Quality Monitoring, National Blood Service (Bristol Centre)
adept

Top of the Page

Our Privacy and Terms and Conditions Statement
All Trademarks Recognised. Copyright © 2008, Adept Scientific.
Site designed and maintained by Adeptise

Adept Scientific | Nydalsveien 33 | 0484 Oslo | Norway | Tel: 800 58 997